Re-calibrating the thermostat
If you need to re-calibrate the thermostat follow these
instructions:
1. Press and hold the OFF button to turn the thermostat off.
2. PressandholdtheONbuttonuntilthetemperature
appears on the screen.
3. Usetheup/downbuttonstosetthenewtemperature.
4. PressDONEtoaccept.
5. PresstheONbuttononcetoturnthethermostatbackon.
Error Codes
E0 = The internal sensor has developed a fault.
E1 = The remote floor probe has not been connected, has
been wired incorrectly or the probe is faulty.
E2 = The remote air probe has not been connected, has
been wired incorrectly or the probe is faulty.